Service Manual · Heritage 1854

The
Model 253

DYNABEAT · 9¾ by 12¾ Ligne Electric

The DYNABEAT: a high frequency electric running at 28,800 beats per hour, against the 21,600 of the Model 40. Four assemblies differ from the Models 40 and 50, and the manual names them.

Electric 28,800 bph DYNABEAT High Frequency
The Model 253 movement, dial side and movement side
Factory Service Manual · Model 253 · Dial Side & Movement Side
Technical Specifications
Ligne9¾ by 12¾
Dimensions22.1 by 28.7 mm
Beat28,800 per hour
PowerTimex energy cell Type A
Replace cell below1.5 V
Minimum amplitude480°
Factory oilMoebius Synt-a-lube
ManualService Manual · Model 253
Height6.10 mm
Jewels3
Height and jewels: ranfft.org

The High Frequency Electric

The Timex Model 253 is a 9¾ x 12¾ ligne electric watch movement featuring a high frequency balance system. It operates at a rate of 28,800 beats per hour. The rate can be checked on all conventional watch rate recorders having a setting for 28,800 beats per hour, and may also be checked on some recorders using a setting for 14,400 or 21,600 beats per hour.

What is different: In the Model 253, the contact spring assembly, seconds wheel assembly, index wheel assembly and balance wheel assembly are different from the similar Timex Model 40 and Model 50 parts. The rest of the architecture, stem bracket and all, is shared.

The Model 253 is powered by a Timex energy cell Type A. Timex recommends replacement only with the genuine Type A cell; use of a cell not meeting Timex specifications may cause the watch to malfunction. The Timex code number on the edge of the dial gives the catalog number, movement number and year of manufacture.

Caution: Since the watch contains permanent magnets, no attempt should be made to demagnetize it.
Timex Model 253, dial side
Dial side
Timex Model 253, movement side
Movement side
Photos courtesy of ranfft.org

Exploded View

9433 is the stop lever here rather than the set spring of the earlier electrics, and 4035 is the energy cell connector.

Model 253 movement, exploded view
Model 253 · 29 Components
Ref.Component
100Plate Assembly
110Train Wheel Bridge Assembly
121/1Balance Bridge Assembly
145Dial Rest
200/2Friction Pinion
200/3Friction Spring
206Center Wheel Assembly
210Third Wheel Assembly
227Seconds Wheel Assembly
255Hour Wheel Assembly
260Minute Wheel Assembly
401/1Setting Stem with Crown
495/3Stem Bracket
498Friction Washer
498/1Hour Wheel Washer
721Balance Wheel Assembly
740Hairspring Wedge Pin
751Dial
850Hour Hand
851Minute Hand
852/1Sweep Second Hand
4020/1Shunt Bridge
4035Connector, Energy Cell
4080Contact Spring Assembly
4330Index Lever Assembly
4360Index Wheel Assembly
5121/1Balance Bridge Screw
9433Stop Lever
54020/1Shunt Bridge Screw

Disassembly

Getting the movement out of its case first? Case types and dust seals

The Caseback and Cell

1

Insert a blade into the opening on the bezel and pry the caseback off. The locating tab on the caseback is used for orientation of the back during reassembly.

2

Remove the energy cell. Lift off the movement cover; it is held in place by two tabs which snap into recesses in the bezel.

Note: Any energy cell with a voltage of less than 1.5 volts, or one in service in excess of one year, should be replaced. Use of an energy cell not meeting Timex specifications may cause the watch to malfunction.
The caseback, locating tab, energy cell, opening notch, case and locating notch
Fig. 253.3 · Caseback & Cell

The Movement Cover

•

The cover and the tab which snaps into the bezel, with the movement beneath.

The movement cover, its tab and the movement in the bezel
Fig. 253.3 · Movement Cover

Releasing the Stem

3

The stem is held in position by the stem bracket. Pull the stem out into the set position and continue to maintain a slight outward pull.

4

Place the points of a heavy tweezer into one side of the stem bracket and push the bracket aside to release one side of the stem. Continue to pull the stem outward and use the tweezer points to release the other side. The stem will now pull free of the movement and bezel.

Inserting tweezers at the stem bracket to release the setting stem
Fig. 253.4 · Stem Bracket

Out Through the Crystal

5

After the stem is removed, the movement can be removed through the crystal side of the bezel. Remove the crystal with a crystal seating tool and then lift the reflector ring and movement free of the bezel.

Note: Note the position of the movement locating tabs inside the bezel. Tabs should properly align in the notches of the plate when reassembling the watch.
The crystal, reflector ring, movement and dial assembly, and bezel
Fig. 253.4 · Case

The Dial

6

Remove the sweep second hand; the minute and hour hands need not be removed.

7

Straighten the four dial tabs enough to remove the dial from the movement.

The dial assembly, four dial tabs and sweep second hand
Fig. 253.5 · Figure A

The Shunt Bridge

8

Remove the shunt bridge screw. Lift the screw end of the shunt bridge off its post and carefully slide the shunt bridge from the movement, noting the tab on its end which engages the plate.

9

Replace the shunt bridge screw.

The shunt bridge and shunt bridge screw
Fig. 253.5 · Figure B

The Balance

10

Remove the hairspring wedge pin; do not distort either the pin or the hairspring. Note the hole in the balance bridge which permits access to the wedge pin.

11

Rotate the balance wheel carefully until the hairspring tail is free of the hairspring bracket and the regulator.

12

Note the position of the energy cell connector, then remove the two balance bridge screws, remove the connector, lift off the balance bridge assembly and carefully remove the balance wheel assembly.

Note: If the wedge pin cannot be loosened through the hole, remove the two balance bridge screws and carefully remove the balance bridge and balance wheel assembly from the movement to permit access to the wedge pin.
The wedge pin, balance bridge screws, balance bridge assembly, balance wheel assembly and energy cell connector
Fig. 253.5 · Figures C and D

Cleaning

The best way to clean the Model 253 movement is to disassemble it only to the point of removing the balance bridge and the balance wheel assembly. The movement should be placed in the watch cleaning machine, including ultrasonic baths, preferably on edge to insure proper drainage of the fluids. The movement must be immersed in two sets of rinsing fluid, and the final rinsing solution must be absolutely clean. After cleaning is completed, the movement must be thoroughly dried.

The balance wheel assembly must be cleaned separately in order to prevent damage to the balance staff points and the hairspring. Other metal parts may be cleaned in the same manner as the movement. Only standard watch cleaning solutions should be used.

Caution: care must be exercised when cleaning cases, dials, hands, special rings and so on, which may contain materials other than metal, because paint, lacquer and plastic finishes can be damaged by some standard watch cleaning solutions.

Lubrication

Apply non-spreading type oil, Moebius Synt-a-lube in the factory, to the minute pinion stud at the top of the minute pinion; both pivots of the index lever; both pivots of the index wheel pinion; both pivots of the sweep seconds pinion; the back pivot of the third wheel assembly; the junction of the minute wheel with the dial ring; the junction of the minute wheel with the plate assembly, through the stem bracket slot in the train bridge; the index wheel on the driving face of three teeth; the index lever fork where it contacts the impulse pin; and the friction washer and sweep second pinion bearing surface at their junction.

Front View

•

The dial ring, minute pinion, index lever pinion, index wheel pinion, sweep seconds pinion and minute wheel.

Front view oil points on the Model 253
Fig. 253.7 · Front View

Back View

•

The plate assembly, minute wheel through the stem bracket slot, third wheel assembly, index wheel and index lever. Point A is the root of the minute pinion teeth and point B the friction pinion at its junction with the plate assembly.

Back view oil points on the Model 253
Fig. 253.7 · Back View

Filling the V-Conic Bearings

•

Fill the V-conic bearings three eighths to five eighths full, by depth.

Cross section of a V-conic bearing showing the fill depth
Fig. 253.7 · V-Conic Bearing

Apply spreading type oil, Woods AAAA in the factory, to the root of the minute pinion teeth, point A in the front view, to lubricate the minute wheel pinion pivot; and to the friction pinion at its junction with the plate assembly, point B.

Apply watch grease, Hamilton PML in the factory, to the set stem bracket, set stem teeth and bearing surface below the teeth, prior to assembly of the stem to the watch head.

Water resistant models: apply grease, Moebius special lubricant in the factory, to half of the exposed circumference of the crown gasket before assembly of the stem to the watch head.

Operation & Contact

Running on the Bench

•

Disassemble as far as removal of the dial. Replace the stem, push into the run position and place the movement on a suitable movement ring. Place the energy cell in position and secure with an energy cell retaining spring, available on request from the Timex material sales division.

•

With the energy cell in place the movement should start to run and the balance wheel assembly will oscillate. If it fails to start immediately, slight rotation of the watch may be necessary. Check that the sweep second staff is moving.

Note: A minimum balance amplitude of 480° indicates the watch is in satisfactory condition.
The Type A energy cell held by the retaining spring
Fig. 253.8 · Figure A

Where the Cell Touches

•

The negative pole of the energy cell must touch the contact spring assembly. Never permit metallic contact between insulated and uninsulated parts of the movement, as the short circuit will reduce the life of the cell.

The contact spring and the negative pole position
Fig. 253.8 · Figure B

The Contact Closing

•

Rotate the balance assembly slowly from the rest position using very light pressure, a clean brush. The instant the contact spring touches the contact pin on the balance, current flows through the balance coil. The current induces a magnetic field which opposes the field of the permanent magnet and imparts an impulse to the balance assembly.

The contact spring and contact on the balance assembly
Fig. 253.9 · Figure C

The Contact Jewel

•

The purpose of the contact jewel is to limit the contact between the contact spring and the contact pin, so that the flow of current occurs at the proper position during the rotation of the balance assembly.

The contact pin, contact spring and contact jewel
Fig. 253.9 · Figure D

The Return Stroke

•

After the balance returns to its neutral position the same contact process is repeated in the opposite direction. This action is the source of mechanical power to drive the movement.

The contact made on the opposite swing
Fig. 253.9 · Figure E

Where the Contact Spring Points

•

The position of the contact spring is critical. The spring must be pointing exactly at the centre of the balance staff, or V-conic bearing.

Caution: Protect the contact spring from scratches and deforming, avoid excessive bending, and do not touch the contact area at the end of the spring. Do no rubbing, grinding or polishing on either side in this area. Do not attempt to adjust the length of the contact spring, and do not permit any watch lubricant near the contact pin, contact jewel or contact spring.
The contact spring aimed at the V-conic bearing
Fig. 253.10 · Figure F

Centred Between Disc and Balance

•

It should be centred horizontally between the impulse disc and the balance wheel.

Cross section showing the contact spring, impulse disc, balance and contact jewel
Fig. 253.10 · Figure G

The Index Train

Taking the Train Bridge Off

•

Remove the balance bridge and balance wheel assembly, then the shunt bridge screw. Lift off the train wheel bridge being careful not to disturb the loose parts, and note the position of the various parts on the plate assembly.

•

The dial rest and minute wheel assembly may be removed from the bottom of the plate assembly without disturbing the gear train. Lift the stem bracket, stop lever and contact spring assembly off the plate assembly without disturbing the gear train.

•

The third wheel assembly is driven by the pinion on the seconds wheel assembly. The seconds wheel assembly is driven by the pinion on the index wheel assembly.

The train wheel bridge, index wheel, seconds wheel, third wheel, contact spring, stem bracket, stop lever, minute wheel and dial rest
Fig. 253.11 · Figure H

Clockwise: the Advance

•

The impulse pin on the balance assembly, when moving clockwise, engages with the fork on the index lever and moves the lever counterclockwise. Pin D on the index lever engages with the index wheel.

•

The three magnets, round pins mounted in the plate assembly and labelled A, B and C, attract the tips of the index wheel teeth and move the wheel clockwise the remaining part of a tooth. Magnet C also attracts the draw lever on the index lever and holds it in position until moved by the impulse pin.

The index wheel, index lever, magnets A, B and C, pins D and E and the banking ears on the plate
Fig. 253.12 · Figure J

Counterclockwise: the Correction

•

When the impulse pin moves counterclockwise it engages the fork and moves the index lever clockwise. Pin D moves out of engagement with the index wheel and pin E moves into engagement.

•

If the index wheel is not positioned correctly by the magnets, pin E turns the index wheel to the correct position so that the next engagement of pin D will advance the index wheel clockwise. Clockwise rotation of the index wheel drives the movement gear train.

The draw lever, index lever, balance staff, index wheel and impulse pin
Fig. 253.12 · Figure K

The Friction Pinion

•

Setting friction for the dial train is provided by a spring connecting the friction pinion and the third wheel. The friction pinion and third wheel may be separated by lifting the friction pinion with tweezers; it is not necessary to remove the friction spring from the third wheel. To reassemble, press the friction pinion firmly back into place in the third wheel.

Cross section of the third wheel, friction spring, friction pinion, hour wheel and center wheel
Fig. 253.13 · Figure L

Running Position

•

The balance stop mechanism is purely mechanical. In the running position the tip of the stem butts against the stop lever and keeps the tip of the stop lever away from the impulse disc.

The stop lever held clear of the impulse disc by the crown set stem
Fig. 253.13 · Figure M

Stop Position

•

With the stem pulled out into the set position, the tip of the stop lever butts against the impulse disc on the balance wheel assembly and stops it. In the stopped position there is no current drain to shorten the life of the energy cell.

The stop lever against the impulse disc
Fig. 253.13 · Figure N

The Seconds Wheel Friction Washer

•

A friction washer is located between the plate and the seconds wheel, domed slightly. Check that it has not become damaged during disassembly. Too much friction will cause too great a drag on the movement; too little will cause an erratic sweep second hand action.

•

A tab on one leg of the friction washer fits into a slot in the plate to prevent it from turning.

The seconds wheel, friction washer and plate
Fig. 253.14 · Figure Q

The Dome

•

The dome is .010 approximately, twice the thickness of the seconds wheel.

The friction washer dome, .010 approximately
Fig. 253.14 · Figure P

Reassembly

1

Place the minute wheel assembly in the dial rest, then carefully position the plate assembly on top of the dial rest.

2

Third wheel assembly

3

Friction washer

4

Index lever assembly

5

Index wheel assembly

6

Seconds wheel

7

Stem bracket

8

Stop lever

9

Contact spring assembly

10

Train wheel bridge assembly, secured with the shunt bridge screw

The third wheel: place the friction pinion, pinion side down, on a flat anvil. Place the plate assembly over the friction pinion. Snap the third wheel assembly, with the friction spring in position, onto the end of the friction pinion.

Refitting the Balance

•

Assemble the balance bridge assembly to the movement with the two balance bridge screws, leaving the screws loose. Tilt the balance wheel assembly and carefully insert the pivot on the hairspring side into the V-conic bearing, then the other pivot into the other V-conic bearing.

•

Tighten the balance endshake adjusting screw enough to hold the balance wheel assembly in place, then place the energy cell connector in position.

The balance endshake adjusting screw and energy cell connector
Fig. 253.15 · Figure R

The Hairspring and Regulator

•

Insert the end of the hairspring into the slot in the regulator and then into the hole in the hairspring bracket by rotating the balance wheel and guiding the end of the spring. Check that the impulse pin is in the slot of the index lever, then secure the hairspring in the bracket with the wedge pin.

•

The hairspring should be levelled, centred and in light permanent contact with the inside edge of the regulator slot and the regulator tab. It must not leave those contact points at any time with the regulator within normal regulating range.

•

Adjust the level by grasping the spring as close as possible to the pinning point. To adjust centring, grasp 160° to 180° from the pinning point. To keep the spring in permanent contact with slot and tab, carefully bend the tab towards the centre of the spring.

Caution: Adjust the balance wheel endshake using caution to apply minimum downward pressure, which could damage the points of the balance staff. Loosen the shunt bridge screw, slide the shunt bridge under the hairspring and secure with the shunt bridge screw.
The regulator slot, regulator tab, hairspring, bend area, wedge pin and wedge pin bracket
Fig. 253.16 · Figure S

Preposition the hands at 12 o’clock on the dial, then position the dial assembly on the movement so the dial tabs pass through the plate assembly. Hold the dial in place and bend the tabs to secure it on the plate. Drive the sweep second hand onto the end of the sweep second staff, being sure the hand is below the chamfer on the staff.

Place the movement and dial assembly in the case, being careful to position it on the locating tabs, and replace the crystal to secure the movement. Insert the crown and stem assembly with a turning motion to assure engagement in the stem bracket. Put a fresh Timex energy cell Type A in place, positive side up, position the caseback and snap it closed. Push the crown in and the watch will start; if it does not, slight rotation may be necessary to restart the mechanism.